4.2 Leakage from SF6 - filled equipment p.15 4.3 Maintenance of SF6 - filled equipment p.15 4.4 End of life of SF6 - filled equipment p.16 4.5 Abnormal situations p.16 4.6 SF6 and the global environment p.19 5 Conclusions p.21 Appendix 1: bibliography p.22 The general properties of SF6 gas and its SF6 by-products are presented.

[email protected]
News Detail
  • SF6 By-products: Safety, Cleaning, and Disposal Concerns

    • IEC TR 61634 (SF 6 Handling) • IEC TR 60480 (Used SF 6) • EPA’s EPS Partnership Web site – Byproducts of SF6 Use in the Electric Power Industry, January, 2002 – Partner SF 6 Handling Procedures – Service Provider Directory – Catalog of Guidelines and Standards for the Handling and Management of SF 6

    Get Price
  • IEC 60376 - Specification of technical grade sulphur

    IEC 60480 - Specifications for the re-use of sulphur hexafluoride (SF6) and its mixtures in electrical equipment Published by IEC on April 1, 2019 This document provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life)....

    Get Price
  • Edition 3 .0 2019-04 INTERNATIONAL STANDARD NORME INTERNATIONALE

    INTERNATIONAL ELECTROTECHNICAL COMMISSION _____ SPECIFICATION S FOR THE RE-USE OF SULPHUR HEXAFLUORIDE (SF6) AND ITS MIXTURES IN ELECTRICAL EQUIPMENT . FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees).

    Get Price
  • IEC specifications for SF6 gas - DILO

    Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification.

    Get Price
  • IEC 60376:2018 | IEC Webstore

    IEC 60376:2018 defines the quality for technical grade sulphur hexafluoride (SF 6) and complementary gases such as nitrogen (N 2) and carbon tetra-fluoride (CF 4), for use in electrical equipment.

    Get Price
  • Byproducts of Sulfur Hexafluoride (SF6) Use in the Electric

    the decomposition products and concentrations formed under actual conditions can vary depending on the equipment used and the type of electrical discharge (CIGRE 1997). 1 CIGRE (the International Council on Large Electric Systems) is a permanent non-governmental and non­ profit-making international association based in France.

    Get Price
  • IEC 61634 : 1.0 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - USE AND

    1.9 Guidance for working with SF6 gas and its decomposition products 1.9.1 Equipment life cycle - sections 2 to 6 1.9.2 Technical information SECTION 2: WORKING WITH NEW SF6 GAS 2.1 Purchasing 2.2 Handling and storage of cylinders 2.3 Equipment for handling new SF6 2.4 Working with new SF6 2.4.1 Indoor working

    Get Price
  • IEC 60480 - Specifications for the re-use of sulphur

    Guidelines for the checking and treatment of sulfur hexafluoride (SF6 ) taken from electrical equipment and specification for its re-use This International Standard concerns the re-use of sulfur hexafluoride (SF6) after removal from electrical equipment (for maintenance, or at the end of life).

    Get Price
  • IEC 60480:2019 - European Standards

    IEC 60480:2019 provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life). Sulphur hexafluoride (SF6), nitrogen (N2) and carbon tetrafluoride (CF4), are gases commonly used for electrical equipment.

    Get Price
  • 24kV SF6 INSULATED SWITCHGEAR SPECIFICATION

    IEC 60376 Specification of technical grade SF6 for use in electrical equipment. EN 61869-2 Instrument transformers - Part 2: Additional requirements for current transformers EN 61869-3 Instrument transformers - Part 3: Additional requirements for inductive voltage transformers EN 50181

    Get Price
  • Guidelines – Sulphur Hexafluoride Management

    representatives involved with the specification, procurement, installation, commissioning, maintenance and decommissioning of SF6 equipment. SF6-filled equipment and cylinders should be managed and tracked in accordance with this guideline. It also applies to Horizon Power staff and their nominated representatives

    Get Price
  • Solvay Special Chemicals

    The ad - dition of 10 % of air by volume reduces the breakdown voltage of SF6by about 3 %, the addition of 30 % air by about 10 %. The breakdown voltage of SF6reaches that of transformer oil at a pressure of only 3 bar (Fig. 25).

    Get Price
  • [PDF] TECHNICAL SPECIFICATION OF 132 KV SF6 CIRCUIT BREAKER

    Aug 07, 2016 · IEC-62271-100 Specification for alternating current circuit breakers 2 IEC-376 Specification and acceptance of new supply of sulfur hexafluoride 3 IS-2147 Degree of protection provided for enclosures for low voltage switch gear and control gear 4 IS-325 Specification for three phase induction motors 5 IS-13118

    Get Price
  • SF6 Decomposition in Gas-Insulated Equipment - IEEE Journals

    Abstract: The increasing application of SF6 as an insulating gas has led to many studies on SF6 decomposition in gas-insulated equipment. In the presence-of an electric arc, spark or corona, SF6 decomposes to a wide variety of chemically active products which possess completely different properties from SF6.

    Get Price
  • Myth About SF6 Gas In Electrical Equipment

    May 25, 2020 · Buildings containing SF6-filled indoor equipment should be provided with ventilation; natural ventilation would normally be adequate to prevent the accumulation of SF6 released due to leakage (see IEC 61634, sub-clause 3.4: “Safety of personnel” and IEC 61936-1). Type and extent of required measures depend upon location of the room, the

    Get Price
  • The SF6-ReUse-Process A contribution on the sustainability of SF

    the used SF6 is regenerated into new virgin gas. SF6 which has been regenerated by Solvay fulfills even a higher specification than that required by IEC 60376, as illustrated in Table 1. In order to be able to transform the used SF. 6 . gas back into new virgin SF. 6 . the used gas must fulfill the so-called SF. 6 – ReUse – Specification in

    Get Price
  • SF6 gas handling - DILO

    However, DILO separating units allow the SF 6 gas mixture to be purified to the extent that it even meets the standards of IEC 60376 (directive for new SF 6 gas technical quality) with regard to moisture, SF 6 percentage and decomposition products (SO 2).

    Get Price
  • SF6 properties, and use in MV and HV switchgear

    4.2 Leakage from SF6 - filled equipment p.15 4.3 Maintenance of SF6 - filled equipment p.15 4.4 End of life of SF6 - filled equipment p.16 4.5 Abnormal situations p.16 4.6 SF6 and the global environment p.19 5 Conclusions p.21 Appendix 1: bibliography p.22 The general properties of SF6 gas and its SF6 by-products are presented.

    Get Price
  • SULFUR HEXAFLUORIDE FOR ELECTRICAL INSULATING - SF6

    SULFUR HEXAFLUORIDE (SF6) FOR ELECTRICAL INSULATING: A colorless, odorless, non-toxic, liquified gas.

    Get Price
  • SLOVENSKI STANDARD SIST EN IEC 60480:2019

    SIST EN IEC 60480:2019 01-september-2019 SIST EN 60480:2005 Nadomešča: Specifikacija za ponovno uporabo žveplovega heksafluorida(SF6) in njegovih mešanic v električni opremi Specification for re-use of SF6 and its mixtures in electrical equipment Ta slovenski standard je istoveten z: EN IEC 60480:2019 29.040.20 Izolacijski plini Insulating

    Get Price
  • sf6 Gas Mixture Decomposition value

    Use and handling of sulphur hexafluoride (SF) and its mixtures IEEE C37.122.3-2011 – IEEE Guide for Sulphur Hexafluoride (SF 6) Gas Handling for High-Voltage (over 1000 Vac) Equipment IEC 60480:2004 - Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use

    Get Price
  • Gas-Insulated Substations - GIS - Electrical Engineering Portal

    SF6 decomposes in the high temperature of an electric arc, but the decomposed gas recombines back into SF6 so well that it is not necessary to replenish the SF6 in GIS. There are some reactive decomposition byproducts formed because of the trace presence of moisture, air, and other contaminants. The quantities formed are very small.

    Get Price
  • IEC 60480 GUIDELINES FOR THE CHECKING AND TREATMENT OF SULFUR

    8 Quality specification for re-use of SF6 in new or existing switchgear 8.1 Decision flowchart for SF6 removed from electrical equipment for treatment As a guide for the operator, the following flowchart (Figure 1) defines the selection procedure to determine the best use of SF6 after removing it from equipment for potential treatment.

    Get Price
  • Questions Misconceptions about GIS SF6 Gas Systems

    Feb 01, 2012 · IEC 60480: Guidelines for the Checking and Treatment of Sulfur Hexafluoride (SF6) taken from Electrical Equipment and Specification for its Re-use IEC 62271-1: High-voltage switchgear and control gear -Part 1 -Common specifications. ASTM D2472: Standard Specification for Sulfur Hexafluoride

    Get Price
  • Standard - Guidelines for the checking and treatment of

    Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use - IEC 60480:2004Concerns the re-use of sulfur hexafluoride (SF6) after removal from electrical equipment (for maintenance, or at the end of life)

    Get Price
  • The decomposition products of sulfur hexafluoride (SF6

    Nov 01, 2007 · 1.. IntroductionSulfur hexafluoride (SF 6), molecular weight 146.07, is a colorless, odorless, nonflammable and heavy gas with excellent electrical characteristics that make it applicable for some special uses in the electrical/electronic equipments, industrial processes, scientific fields and commercial products , , .

    Get Price
  • Online Dew Point Monitoring of SF6-Gas-Insulated Equipment

    properties of SF6 and to reduce the formation of corrosive by-products from SF6 decomposition, the amount of water vapor in gas-insulated high-of water molecules may increase the moisture level, especially as equipment ages. Traditionally, moisture level has been checked using periodically taken gas samples, but in recent years

    Get Price
  • Use and handling of sulphur hexafluoride (SF

    IEC 60480:2004 - Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use ENA National Electricity Network Safety Code (Doc 01-2008) 4.0 DEFINITIONS AND ABBREVIATIONS Closed pressure system SF 6 containing equipment that is replenished only periodically by manual

    Get Price
  • 34 Questions And Answers To Break the Myth About SF6 Gas In

    IEC 60480 Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use -The End- For SF6 GIS equipment,it is necessary to use an Ultra High Sensitivity SF6 Trace Gas Leak Detector to find the leak and fault point.

    Get Price