News Center
SF6 End-of-life training IEC specifications

SF6 End-of-life training IEC specifications

Jul 21, 2018 · SF 6 and its handling are subject to a number of publications, especially from CIGRÉ. However, the most familiar ones for GIS project execution are the IEC standards IEC 60376 (2005–06) (for new gas), IEC 60480 (2004–10) (for used gas), and IEC 62271-4 (2013–08) (for handling of SF 6 in high-voltage switchgear).

[email protected]
News Detail
  • IEC 60376 - Specification of technical grade sulphur

    IEC 60480 - Specifications for the re-use of sulphur hexafluoride (SF6) and its mixtures in electrical equipment Published by IEC on April 1, 2019 This document provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life)....

    Get Price
  • Edition 3.0 2018-05 INTERNATIONAL STANDARD

    IEC 60376 Edition 3.0 2018-05 INTERNATIONAL STANDARD Specification of technical grade sulphur hexafluoride (SF6) and complementary gases to be used in its mixtures for use in electrical equipment

    Get Price
  • SF6 By-products: Safety, Cleaning, and Disposal Concerns

    • IEC TR 61634 (SF 6 Handling) • IEC TR 60480 (Used SF 6) • EPA’s EPS Partnership Web site – Byproducts of SF6 Use in the Electric Power Industry, January, 2002 – Partner SF 6 Handling Procedures – Service Provider Directory – Catalog of Guidelines and Standards for the Handling and Management of SF 6

    Get Price
  • IEC 60480 - Specifications for the re-use of sulphur

    Specifications for the re-use of sulphur hexafluoride (SF6) and its mixtures in electrical equipment This document provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life).... IEC 60480 October 1, 2004

    Get Price
  • IEC 60480:2019 - April 2019

    IEC 60480:2019 April 2019 Specifications for the re-use of sulphur hexafluoride (SF6) and its mixtures in electrical equipment - Spécifications pour la réutilisation de l'hexafluorure de soufre (SF6) et des mélanges contenant du SF6 dans le matériel électrique

    Get Price
  • by Jean-Marc Deux - Schneider Electric

    most cases he will subcontract the end-of-life process to licensed waste managers). Table 2 provides an illustration of some global and regional regulations and standards. During the end-of- life process, the expectation, based on the modern processing tools available, is that less than 0.5% of the recoverable SF 6 volume results in emissions

    Get Price
  • SF6 gas handling - DILO

    However, DILO separating units allow the SF 6 gas mixture to be purified to the extent that it even meets the standards of IEC 60376 (directive for new SF 6 gas technical quality) with regard to moisture, SF 6 percentage and decomposition products (SO 2).

    Get Price
  • SF6 properties, and use in MV and HV switchgear

    4.4 End of life of SF6 - filled equipment p.16 4.5 Abnormal situations p.16 4.6 SF6 and the global environment p.19 5 Conclusions p.21 Appendix 1: bibliography p.22 The general properties of SF6 gas and its SF6 by-products are presented. A brief history of the use of SF6 in switchgear is given. The effects of SF6 on the environment are discussed.

    Get Price
  • SF6 Training and Certification | EA Technology

    SF6 Training and Certification Since the Fluorinated Greenhouse Gas Regulations were revised in 2014, if you carry out any activities that directly involve the recovery or handling of SF 6 from high voltage (HV) switchgear, then you need to have passed a theoretical and practical examination in SF 6 handling and hold a certificate of competence

    Get Price
  • TECHNICAL SPECIFICATION - MahaVitaran

    IEC 62271-100/IEC 60056/ IS 13118 : 1991 Specification for alternating current breakers IEC 62271 – 1/ IEC 60694 Panel design, SF6/ Vacuum Circuit Breakers IEC 60044 –1/ IEC 60185/ IS 2705:1992 Current Transformers IEC 60265/IS 9920 : 1981 High voltage switches IEC 376 Filling of SF6 gas in RMU

    Get Price
  • Recent Evolution IEC

    New IEC SC17A Standards IEC 62271-108: Combined function disconnecting circuit-breakers This standard concerns equipment that combines the circuit-breaker and disconnector functions. It is limited to apparatus where the distance between contacts of the circuit-breaker contribute to the BIL withstand.

    Get Price
  • Guidelines – Sulphur Hexafluoride Management

    IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF 6 ) taken from electrical equipment and specification for its re-use , International Electrotechnical Commission, available from SAI

    Get Price
  • The SF6-ReUse-Process A contribution on the sustainability of SF

    the used SF6 is regenerated into new virgin gas. SF6 which has been regenerated by Solvay fulfills even a higher specification than that required by IEC 60376, as illustrated in Table 1. In order to be able to transform the used SF. 6 . gas back into new virgin SF. 6 . the used gas must fulfill the so-called SF. 6 – ReUse – Specification in

    Get Price
  • Standard - Guidelines for the checking and treatment of

    Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use - IEC 60480:2004Concerns the re-use of sulfur hexafluoride (SF6) after removal from electrical equipment (for maintenance, or at the end of life)

    Get Price
  • Gas-Insulated-Substations SF6 gas handling

    Sep 26, 2011 · Technical recommendation in e.g. Definition in IEC-standards, Application of table 25 SF6 residual pressure less than 2% during maintenance and end of life.

    Get Price
  • Edition 1.0 2013-08 INTERNATIONAL STANDARD NORME INTERNATIONALE

    INTERNATIONAL ELECTROTECHNICAL COMMISSION _____ HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR – Part 4: Handling procedures for sulphur hexafluoride (SF6) and its mixtures FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

    Get Price
  • TECHNICAL SPECIFICATION FOR

    4) IEC 62 271-1/IEC 60694 - Panel design, SF6/Vacuum Circuit Breakers 5) IEC 60044-1/IEC 60185/IS 2705:1992 - Current Transformer 7) IEC 60265/IS 9920:1981 - High voltage switches. 8) IEC 376 - Filling of SF6 gas in RMU. 9) IEC 60273/IS :2099 - Dimension of Indoor Outdoor post insulators with voltage 1000 Volts.

    Get Price
  • SF6 Circuit breaker up to 17.5 kV - Schneider Electric

    b the SF6 gas is under control from production through to the circuit-breaker’s end of life. In particular it can be recovered at the end of the circuit-breaker’s life and re-used after treatment in line with the new European directive, b an end of life manual for the product details procedures for dismantling and recycling components.

    Get Price
  • Myth About SF6 Gas In Electrical Equipment

    May 25, 2020 · According to Clause 7.1 of IEC 60480: “In principle, a mixture of 20% of oxygen and 80% SF6 can be inhaled without adverse effect. Concentrations above 20% would cause suffocation due to lack of oxygen. (*) TRGS 900, Technische Regeln für Gefahrstoffe 23.

    Get Price
  • SF6, Its Handling Procedures and Regulations | SpringerLink

    Jul 21, 2018 · SF 6 and its handling are subject to a number of publications, especially from CIGRÉ. However, the most familiar ones for GIS project execution are the IEC standards IEC 60376 (2005–06) (for new gas), IEC 60480 (2004–10) (for used gas), and IEC 62271-4 (2013–08) (for handling of SF 6 in high-voltage switchgear).

    Get Price
  • Solvay Special Chemicals

    Specifications 37 Packaging for new SF6 according to IEC 60376 38 Solvay’s Responsible Care Programme for SF6 41 Transport of used SF6 42 Life cycle assessment studies for the use of SF6 in high- and medium-voltage applications 43 Product stewardship for SF6 47 Fluorine compounds from Solvay 48 Product range of fluorine compounds 49

    Get Price
  • Sulfur Hexafluoride SF6 Safety Data Sheet SDS P4657

    Formula : SF6 1.2. Relevant identified uses of the substance or mixture and uses advised against Use of the substance/mixture : Industrial use. Use as directed. 1.3. Details of the supplier of the safety data sheet Praxair, Inc. 10 Riverview Drive Danbury, CT 06810-6268 - USA T 1-800-772-9247 (1-800-PRAXAIR) - F 1-716-879-2146 www.praxair.com 1.4.

    Get Price
  • ABB Library - IEC SF6 Mechanical Circuit Breaker HD4

    Training and support. HD4 - IEC Indoor SF6 MV circuit breaker for primary distribution. ID: HD4 according to IEC and GOST standards - Gas insulated MV circuit

    Get Price
  • Reconditioned SF6 Gas Parameters - DILO

    Reconditioned SF 6 Gas Used gas with a better quality than new . Thanks to the combination of several DILO gas separation and preparation units, we can process even extremely contaminated SF 6 gas with to a purity of 99 %.

    Get Price
  • ABB Library - Gas Insulated Primary Switchgear (SF6)

    Product data and specifications. expand_more Promotional material Primary Gas Insulated Switchgear ZX2 Digital SF6 (IEC, GB, ANSI) Training and support.

    Get Price
  • CENTRAL POWER RESEARCH INSTITUTE

    7 IEC – 60480 Guide to checking of sulphur hexafluoride taken from electrical equipment 8 IEC-376 Specification and acceptance of new supply of sulfur hexafluoride 9 IEC: 60947 Degree of protection provided for enclosures for low voltage switch gear and control gear 10 IS-325 Specification for three phase induction motors

    Get Price
  • SPECIFICATION NO.MMC/MSC-II/GIS/18.10.2017 TECHNICAL

    IEC 622271-1 High Voltage switchgear and controlgear-Part-1: Common specification IEC 622271-100 High voltage Alternating current circuit breakers. IEC 60694 Common clauses for high voltage switchgear and control gear standards IEC 622271-103 High voltage switches for rated voltages above 1 KV and less than 52 KV.

    Get Price
  • SafeLink Manual 2009 Rev E

    2.4 Standards Compliance • IEC 62271-1 High – voltage switchgear and controlgear, common specifications. • IEC 62271-102 Alternating current disconnectors and earthing switches. • IEC 62271-105 Alternating current switch-fuse combinations. • IEC 62271-200

    Get Price
  • BS EN 60376:2005 - Specification of technical grade sulfur

    Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment: Status: Superseded, Withdrawn: Publication Date: 02 December 2005: Withdrawn Date: 24 August 2018: Normative References(Required to achieve compliance to this standard) IEC 60050-212, ISO 14040, IEC 60050-826, IEC 60050-441, IEC 61634, IEC 60050-191, IEC

    Get Price
edge-iconMaybe You Will Be Interested
toTop
Click avatar to contact us
Chat Online