Dew Point. -62°C. -40°C. -85°C. Acidity (HF) < 0.3 ppmw. < 0.3 ppmw. < 0.3 ppmw. Hydrolizable Fluorides.

[email protected]
News Detail
  • IEC 60376 - Specification of technical grade sulphur

    IEC 60376. May 1, 2018. Specification of technical grade sulphur hexafluoride (SF6) and complementary gases to be used in its mixtures for use in electrical equipment. This document defines the quality for technical grade sulphur hexafluoride (SF6) and complementary gases such as nitrogen (N2) and carbon tetra-fluoride (CF4), for use in electrical equipment....

    Get Price
  • SULFUR HEXAFLUORIDE FOR ELECTRICAL INSULATING - SF6

    Specifications: 99.9%. Nitrogen Oxygen Air (N2 + O2) SULFUR HEXAFLUORIDE FOR ELECTRICAL INSULATING - SF6. Exceeds ASTM D2472-00 IEC 376 SPECS FOR ELECTRICAL

    Get Price
  • IEC - International Electrotechnical Commission - IEC 60376

    May 24, 2018. Specification of technical grade sulphur hexafluoride (SF 6) and complementary gases to be used in its mixtures for use in electrical equipment. IEC 60376:2018 defines the quality for technical grade sulphur hexafluoride (SF6) and complementary gases such as nitrogen (N2) and carbon tetra-fluoride (CF4), for use in electrical equipment....

    Get Price
  • IEC 60480 - Specifications for the re-use of sulphur

    This document provides criteria for the re-use of sulphur hexafluoride (SF 6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life). Sulphur hexafluoride (SF 6 ), nitrogen (N 2 ) and carbon tetrafluoride (CF 4 ), are gases commonly used for electrical equipment.

    Get Price
  • ASTM D2472 | Sulfur Hexafluoride

    Dew Point. -62°C. -40°C. -85°C. Acidity (HF) < 0.3 ppmw. < 0.3 ppmw. < 0.3 ppmw. Hydrolizable Fluorides.

    Get Price
  • Guidelines – Sulphur Hexafluoride Management

    IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment, International Electrotechnical Commission, available from SAI global http://www.saiglobal.com/ [16]. IEC 60480:2004 Guidelines for the checking and treatment of sulfur

    Get Price
  • IS 13072 (1991): Sulphur hexafluoride for electrical purposes

    At normal room temperatures and pressures it is gaseous and‘has a density of 6.16 g/l at 20 “C and 760 torr (about five times the density of air). Since its critical temperature is 45.6 “C it can be liquefied by compression; it is normally transported as a liquid in cylinders.

    Get Price
  • List of International Electrotechnical Commission standards

    IEC 60480 Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use IEC 60481 Coupling devices for power line carrier systems

    Get Price
  • Section 7 Technical Specification of Design, Supply, Erection

    IEC 62271 HV Switchgear and Controlgear. 2. IEC 60376 Specification and acceptance of new sulphur hexafluoride 3. IEC 60480 Guide to checking of sulphur hexafluoride taken from electrical equipment. 4. IEC 60060 High Voltage test techniques. 5. IEC 60071 Insulation Co-ordination 6. IEC 60099-5 Surge arresters Part 5: Selection and application

    Get Price
  • The SF6-ReUse-Process A contribution on the sustainability of SF

    specifications for new SF. 6 . incl. the non-toxic requirement according to IEC 60376. In case the used gas does not meet the established quality requirements and, thus, cannot be transformed again into virgin new gas the used gas is treated as waste and environmentally friendly destroyed at accredited waste incineration plants. The SF. 6

    Get Price
  • Typical Primary Plant - ElectraNet

    Maximum ambient temperature °C 55 Maximum one hour average temperature °C 48 Maximum twenty four hour average temperature °C 37 Minimum ambient temperature °C -5 Maximum humidity % 100 Maximum average summer humidity % 55 Maximum average winter humidity % 90 Minimum humidity % 15 Maximum solar radiation kW/m2 1.1 Maximum installed altitude m 1000 Maximum wind speed m/s 46 Seismic load hazard factor No. 0.14 Seismic annual probability of exceedance Years 1 in 1000

    Get Price
  • Solvay Special Chemicals

    SF6– a gas with unusual properties5. Areas of application for sulphur hexafluoride. Electrical engineering 6 High-voltage switchgear and switching stations 7 SF6for the Itaipú hydroelectric powerstation 10 Gas insulated transmission line (GIL) 11 Medium-voltage switchgear 12 High-voltage cables and tubular transmission Lines 13 Transformers 13 Other high-voltage applications 14 SF6for particle and electron accelerators15 SF6as a process gas in the 16 semiconductor industry.

    Get Price
  • IEC-60480 | Specifications for the re-use of sulphur

    IEC 60480:2019 provides criteria for the re-use of sulphur hexafluoride (SF 6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life). Sulphur hexafluoride (SF 6), nitrogen (N 2) and carbon tetrafluoride (CF 4), are gases commonly used for electrical equipment.

    Get Price
  • IEC 60376 : Specification of technical grade sulphur

    Description / Abstract: IEC 60376, 3rd Edition, May 2018 - Specification of technical grade sulphur hexafluoride (SF6) and complementary gases to be used in its mixtures for use in electrical equipment. This document defines the quality for technical grade sulphur hexafluoride (SF 6) and complementary gases such as nitrogen (N 2) and carbon tetra-fluoride (CF 4 ), for use in electrical equipment.

    Get Price
  • ASTM C787-11 - Standard Specification for Uranium

    1.1 This specification covers uranium hexafluoride (UF 6) intended for feeding to an enrichment plant. Included are specifications for UF 6 derived from unirradiated natural uranium and UF 6 derived from irradiated uranium that has been reprocessed and converted to UF 6 for enrichment and subsequent reuse. The objectives of this specification are twofold: ( 1) To define the impurity and uranium isotope limits for Commercial Natural UF 6 feedstock so that the corresponding enriched uranium is

    Get Price
  • Sulfur hexafluoride. - Linde Gas

    • a choice of qualities from technical grade according to IEC 60 376/ ASTM D2472-00 to high quality/specialty grades (HiQ®) • typical specification of sulfur hexafluoride 3.0 technical grade is: SF 6 99.9%, H 2O <5 ppm, CF 4 <500 ppm, air <500 ppm • volumes to suit scale and application

    Get Price
  • BS EN 60376:2005 - Specification of technical grade sulfur

    BS EN IEC 60480:2019 Specifications for the re-use of sulphur hexafluoride (SF 6) and its mixtures in electrical equipment 20/30420495 DC BS EN IEC 62271-4. High-voltage switchgear and controlgear.

    Get Price
  • IEC 60480:2019 - European Standards

    IEC 60480:2019. IEC 60480:2019 provides criteria for the re-use of sulphur hexafluoride (SF6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life). Sulphur hexafluoride (SF6), nitrogen (N2) and carbon tetrafluoride (CF4), are gases commonly used for electrical equipment.

    Get Price
  • Standard - Guidelines for the checking and treatment of

    Standard IEC standard · IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF6) taken from electrical equipment and specification for its re-use Subscribe on standards with our subscription service.

    Get Price
  • IEC specifications for SF6 gas - DILO

    Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification.

    Get Price
  • IEC 60376B : 1.0 SPECIFICATION AND ACCEPTANCE OF NEW SULFUR HEXAF

    guidelines for the checking and treatment of sulphur hexafluoride (sf[6]) taken from electrical equipment and specification for its re-use 09/30205410 DC : 0 BS EN 62271-204 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID HIGH-VOLTAGE, GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES OF 72,5 KV AND ABOVE

    Get Price
  • ASTM C787-15 - Standard Specification for Uranium

    1.1 This specification covers uranium hexafluoride (UF 6) intended for feeding to an enrichment plant. Included are specifications for UF 6 derived from unirradiated natural uranium and UF 6 derived from irradiated uranium that has been reprocessed and converted to UF 6 for enrichment and subsequent reuse. The objectives of this specification are twofold: ( 1) To define the impurity and uranium isotope limits for Commercial Natural UF 6 feedstock; and ( 2) To define additional limits for

    Get Price
  • Uranium hexafluoride | UF6 - PubChem

    The potential for release of gaseous UF6, and subsequent generation of its soluble hydrolysis product UO2F2, requires special air-sampling considerations in uranium conversion and gaseous diffusion plants, relative to those plants handling less reactive compounds. In these plants, effective processing, as well as worker safety, requires a high

    Get Price
  • IEC specifications

    Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification.

    Get Price
  • IEC 60480 : Specifications for the re-use of sulphur

    IEC 60480, 3rd Edition, April 2019 - Specifications for the re-use of sulphur hexafluoride (SF6) and its mixtures in electrical equipment This document provides criteria for the re-use of sulphur hexafluoride (SF 6) and its mixtures after recovery and reclaiming from electrical equipment (e.g. for maintenance, at the end-of-life).

    Get Price
  • Earth Fault Protection - Schneider Electric

    IEC 60364-4-42 (subclause 422.3.10) states that it is mandatory to install a residual current device with a sensitivity less than or equal to 300 mA: b on premises with a risk of explosion (BE3)

    Get Price
  • IEC-376 | Specification and acceptance of new sulphur

    IEC-376 › Historical Revision Information Specification and acceptance of new sulphur hexafluoride IEC-376 - 1ST EDITION - SUPERSEDED -- See the following: IEC-60376 Show Complete Document History

    Get Price
  • BTC Investments - Dilo Sf6 Gas Equipment

    750kv-substation-onsite-service. On-site SF6 recovery service is driven by a trailer which equipped with our full set of recovery, refilling, purification equipment and measuring instrument, drive to the substandard gas compartment, perform onsite shutdown and maintenance, directly recover unqualified SF6 gas, recycle and purify them to be qualified and then return to gas compartment, the

    Get Price
  • IEC specifications - us.dilo.com

    Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification.