News Center
IEC specifications sf6 gas reclaimer system

IEC specifications sf6 gas reclaimer system

Oct 17, 2017. DILO Armaturen und Anlagen GmbH has brought a new generation of "SF6 Multi-Analyser" multiple measuring devices to market that allow the SF6 gas quality to be checked easily in accordance with the (EU) F-Gas Regulation and IEC Standard 60480 (reuse specifications). The product makes operation more convenient and offers more options when handling the measuring gas.

[email protected]
News Detail
  • IEC specifications for SF6 gas - DILO

    Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification.

    Get Price
  • IEC specifications

    IEC specifications Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification.

    Get Price
  • IEC specifications

    Relevant IEC specifications/norms for SF6 gas are: IEC 60376 for new gas, IEC 60480 for used SF6 gas and IEC 62271-4 as SF6 reuse specification. CONTACT FORM DIRECT-TRACK

    Get Price
  • IEC 60376 - Specification of technical grade sulphur

    IEC 60376. May 1, 2018. Specification of technical grade sulphur hexafluoride (SF6) and complementary gases to be used in its mixtures for use in electrical equipment. This document defines the quality for technical grade sulphur hexafluoride (SF6) and complementary gases such as nitrogen (N2) and carbon tetra-fluoride (CF4), for use in electrical equipment....

    Get Price
  • SF6 By-products: Safety, Cleaning, and Disposal Concerns

    • IEC TR 61634 (SF 6 Handling) • IEC TR 60480 (Used SF 6) • EPA’s EPS Partnership Web site – Byproducts of SF6 Use in the Electric Power Industry, January, 2002 – Partner SF 6 Handling Procedures – Service Provider Directory – Catalog of Guidelines and Standards for the Handling and Management of SF 6

    Get Price
  • SF6 Gas Handling System - Kaji Tech

    SF6 Gas Handling System Model: KL50V-5.5OL-PⅡ Features: · An original oil-less compressor and oil-free vacuum pump for withdrawal are built-in. · Portable, compact light weight, and liquid SF6 storage type SF6 gas handling system. Specifications: · Gas compressor(14m3/h*, 5MPa=50bar, 5.5kW, direct suction to increase the withdrawal speed).

    Get Price
  • IEC 60376:2005 | IEC Webstore

    This International Standard defines the quality requirements and properties for technical grade sulfur hexafluoride (SF 6) for use in electrical equipment. It covers the properties and methods of test applicable to SF 6 when this substance is supplied for use in connection with any electrical equipment. This second edition differs widely from the first one.

    Get Price
  • SF6 properties, and use in MV and HV switchgear

    Sulphur hexafluoride gas having an equation of state of the Beattie-Bridgeman type, up to temperature of about 1200 K, behaves as a perfect gas: pv2 =R T (v + b) - a where: p = pressure (Pa) v = volume (m3.mol-1) R = ideal gas constant (8.3143 J.mol-1.K-1) T = absolute temperature (K) a = 15.78 x 10-6 (1 - 0.1062 x 10-3 v-1)

    Get Price
  • SF6 Gas Servicing Equipment – ENERVAC INTERNATIONAL ULC

    Convenient and portable handcart mounted SF6 Gas Recovery Unit. Extremely easy to operate. Ideally suited for consolidating partially-used SF6 bottles. Purifies, dries and filters SF6 to 0.1 micron during recovery and re-filling.

    Get Price
  • Edition 1.0 2013-08 INTERNATIONAL STANDARD NORME INTERNATIONALE

    IEC 62271-4 Edition 1.0 2013-08 INTERNATIONAL STANDARD NORME INTERNATIONALE High-voltage switchgear and controlgear – Part 4: Handling procedures for sulphur hexafluoride (SF) and its mixtures – Partie 4: Utilisation et manipulation de l'hexafluorure de soufre (SF 6) et des mélanges contenant du SF 6 INTERNATIONAL ELECTROTECHNICAL COMMISSION

    Get Price
  • SF6-Gas Liquefaction System | WOOSUNG VACUUM TECH - Komachine

    Product Specifications - Power: 220/3380V, 50/60Hz, 3Ph - Recovery rate: 99% - Work Gas: SF6-Gas - Amount of storage: 150~2000L - Gas purity: 99% (MAX) - Amount of temperature: -10~50ºC. Product Feature - It is optimum is purity maintenance of gas because it is stored in liquid form. - An excellent recovery rate and a short recovery time

    Get Price
  • SF6 gas handling - DILO

    After the separating process the gas complies with the quality criteria for reuse stipulated in the IEC 60480 directive. However, DILO separating units allow the SF 6 gas mixture to be purified to the extent that it even meets the standards of IEC 60376 (directive for new SF 6 gas technical quality) with regard to moisture, SF 6 percentage and decomposition products (SO 2 ).

    Get Price
  • 24kV SF6 INSULATED SWITCHGEAR SPECIFICATION

    The insulating medium for the switchgear shall be Sulphur Hexafluoride (SF6) gas. The SF6 gas shall comply with IEC 60376. The operating pressure of the SF6 gas shall be specified and monitored and also facilities for topping-up the SF6 gas shall be provided, in case of non hermetically sealed enclosures.

    Get Price
  • Sulfur hexafluoride (SF6) Recycling Program for Out of

    Standard Operating Procedure SF6 • SET Crew mobilizes to Substation and places job trailer near interrupters to be recycled. • Interrupters are staged in an area by Exelon prior to our crews arrival. • No recovery shall be conducted on an interrupter that is still in service. • Utilizing Vacuum recovery system crew removes SF6 through a

    Get Price
  • Edition 1.0 2013-08 INTERNATIONAL STANDARD NORME INTERNATIONALE

    The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes International Standards for all electrical, electronic and related technologies. About IEC publications The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the

    Get Price
  • General Technical Specification For 220kV SF6 GIS

    Dec 23, 2017 · SF6 GIS The SF6 gas insulated metal enclosed switchgear shall be totally safe against inadvertent touch of any of its live constituent parts. It should be designed for indoor application with meteorological conditions at site (winter 3°C to 14° C and summer 31° C to 46° C, seismic zone: IV).

    Get Price
  • Gas-Insulated Substations - GIS

    SF6 is supplied in 50-kg gas cylinders in a liquid state at a pressure of about 6000 kPa for convenient storage and transport. Gas handling systems with filters, compressors, and vacuum pumps are commercially available. Best practices and the personnel safety aspects of SF6 gas handling are covered in international standards (IEC, 1995).

    Get Price
  • SF6 GAS RECOVERY UNIT - GRU-8 SERIES SPECIFICATIONS

    SPECIFICATIONS DIMENSIONS: Height: 74” (1900 mm) Width: 45” (1140 mm) Depth: 58" (1470 mm) Weight: 950lbs (432kg) STANDARD VOLTAGE: 220V-1PH -50/60 Hz (other voltages available on request) SYSTEM PERFORMANCE: Ideal for breakers up to 256kV SF 6 gas transfer rates up to 112lbs/51kgs per hour <1mbar residual SF 6 gas pressure

    Get Price
  • Questions Misconceptions about GIS SF6 Gas Systems

    Feb 01, 2012 · moisture (water vapor) in the gas begins to condense as liquid (droplets or dew) or solid (ice). Typical dewpoint in SF6 equipment ranges from -60C to -5C. Common operating pressures are 100-755 kPa abs. (0-95 psig). ppmv: Moisture Volume concentration (parts per million by 15 1/18/2012 Volume). One million times the ratio of the volume of moisture

    Get Price
  • SF6 Gas Insulated Switchgear Guide Specification

    The applicable codes and standards listed below should be considered as part of this specification. The latest revision in effect at time of inquiry shall apply for all standards referenced. ANSI/IEEE C37.71, Standard for subsurface dead front switchgear. ANSI/IEEE C37.72, Standard for padmount dead front switchgear. ASTM D2772-SF6 gas requirements

    Get Price
  • Medium voltage switchgear - Schneider Electric

    Insulating Mediums – SF6 SF6 as an interrupting and/or insulating medium Sulphur hexafluoride (SF6) is used as a switchgear interrupting medium from 1 to 800kV Non-flammable Arc-quenching Non-toxic Inert Odourless Highly stable gas Heavy gas Two different types of arc control device, both relying on extending and cooling the arc

    Get Price
  • GAS INSULATED SWITCHGEAR

    IEC 62271-1 High-voltage switchgear and control gear Part 1: Common specifications IEC 62271-203 HV metal enclosed switchgear for rated voltage of 72.5kV and above IEC 62271-100 High-voltage alternating-current circuit breakers.

    Get Price
  • SF6 gas recovery unit - AGRU-8 series

    The operation consists of a simple 2-valve system that can be used to recover up to 99.99% of SF6 gas in one cycle. The operation schematic is given below: Suction and Compression: The AGRU-8 series gas recovery units use sophisticated and durable suction and compression machinery that allows for powerful suction and further compression of SF6 gas.

    Get Price
  • Analyzers Check SF6 Gas Quality | TD World

    Oct 17, 2017. DILO Armaturen und Anlagen GmbH has brought a new generation of “SF6 Multi-Analyser” multiple measuring devices to market that allow the SF6 gas quality to be checked easily in accordance with the (EU) F-Gas Regulation and IEC Standard 60480 (reuse specifications). The product makes operation more convenient and offers more options when handling the measuring gas.

    Get Price
  • Intellirent products category

    Dilo SF6 Mini Plus Portable Recovery System MP B143R01 Series II is a fully functional portable oil-less SF6 gas-reclaimer designed for today’s smaller volume circuit breakers. It has all the features found on larger systems but remains compact and easy to operate.

    Get Price
  • SF6 Gas Services Management | Concorde Specialty Gases

    SF6 Gas Management and Tracking System. Our rigorous SF6 gas handling procedures and inventory control system: ConcordeTrak is the engine behind our quality and control department. It begins as a tracking system behind the scenes, accumulating important historical and current cylinder data.

    Get Price
  • SC System VI Switchgear Detailed Functional Indoor and

    2.01 SF6 -Gas Insulation (a) The SF6 gas shall conform to ASTM D2472. (b) The switchgear shall be filled with SF6 gas to a pressure of 7 psig at 68º F. (c) The gas-tight tank shall be evacuated prior to filling with SF6 gas to minimize moisture in the tank. (d) The switchgear shall withstand system voltage at a gas pressure of 0 psig at 68º F.

    Get Price
  • NEC High Voltage Gas Insulated Switchgear Design Requirement

    GIS Switchgear Gas System. The insulating and interrupting medium shall be SF6 gas, conforming to IEC 60376 or ASTM D 2472. Assembly shall be divided into bays, and each bay into gas-tight and arc- resistant compartments, to confine the effect of any fault to the respective compartment. Minimum compartmentalization shall be as follows: a.

    Get Price
  • ENERVAC - GRU-4 Series - ENERVAC - SF6 Gas Servicing

    ENERVAC’s latest SF6 Gas Recovery Unit incorporates a new and improved high pressure,totally oil-less compressor capable of 1000 psig (7 MPag) of pressure. This new technology allows for liquefaction of SF6 gas even in the warmer climates typical of the southern United States.The cart is ideally suited for servicing small volume SF6 equipment.

    Get Price
edge-iconMaybe You Will Be Interested
toTop
Click avatar to contact us